默认 spalled brick directly above steel relieving angle

spalled brick directly above steel relieving angle
i have a 40 year old concrete framed building with brick face and six inch block backup. brick over windows is supported by concrete lintels that extend from the spandrel beams. the adjacent brick beyond the windows sits on steel relieving angles bolted to spandrels at the same elevation as the concrete lintels. the brick directly over the relieving angles is spalled. what is causing this and can it be repaired?
possible moisture being trapped behind the brick and wicking through the brick or mortar joint. are there brick vent holes? not sure where you're located but could be subject to freeze-thaw and with the trapped moisture, the brick surface has exfoliated. spalled brick is usually indicative of a water/vapour/moisture problem. it's necessary to determine the source.
dik
i would suggest the same thing as dik. look for moisture as the root cause.
spalling is caused by moisture entrapment, and is especially sensitive in free-thaw areas as mentioned. another factor leading to spalling is low porosity, which in some areas is difficult to avoid.
i don't know of ways to repair spalling brick once they're in place. you may be able to paint them to prevent further spalling by minimizing moisture soakage.
i should also point out that coating them may not help at all. it is difficult to get water out of brick, and you may see spalling even after coating.
macmet - i was wondering if the sealing over the brick will envelope any existing moisture that is currently in brick that may dry out?
it might, that's what i meant when i said it might still spall even after coating. it is difficult to eliminate moisture held within bricks.
how bad is the spalling? is your concern structural or cosmetic?
there really isnt any way to keep all the water out of the brick, but a siloxane water repellant is a good idea. it breathes so moisture can exit, and it will do as good or better as anything else for keeping moisture out. it is really good stuff.
it is also possible the reason for the spalling is rust on the steel angles. rust basicly expands the steel, and the pressure behind or below the brick can cause spalling. a common solution would be to remove the brick, clean and coat the angle with rust preventive coating, replace the spalled brick, and apply water repellant.
another possibility might be that the weep holes or vents are either partially or completely filled with mortar or other debris. as a result, the lower brick may become saturated and then freeze thaw will spall the face of the brick.
it could also be that someone caulked along the line of the weep holes. everytime, i think that i have seen it all, i will discover another amazement.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
brick veneer on 4-story wood bldg huangyhg 产品功能分析 0 2009-09-07 04:57 PM
brick residential roofwall detail huangyhg 产品功能分析 0 2009-09-07 04:53 PM
brick cladding deflection limits huangyhg 产品功能分析 0 2009-09-07 04:48 PM
brick cladded wood studs huangyhg 产品功能分析 0 2009-09-07 04:47 PM


所有的时间均为北京时间。 现在的时间是 12:23 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多