roof wind load on drawings
i am used to seeing plans that include the wind load resistance required of the components and cladding. further this information is usually provided by the structural engineer and is given in psf. my current project's plans (beachside florida) just say 150 mph wind. shouldn't the structural engineer be the one to convert that to psf for each different area?
check out our whitepaper library.
you could always ask for that
it seems customary to do this, especially in florida.
the florida building code requires component and cladding pressures to be specified on the drawings either in a tabular format or graphically on an elevation. am not in the office right now and can't point to which section in the code.
thanks for replies - i have asked and assume i will get an appropriate answer - well i will get an answer, i just hope a simple request will suffice.
slickdeals - i looked in the codes but have not found it yet - if you find it i'd appreciate hearing from you.
i'm the owners rep on this project, trying to get timely answers for the contractor from slow responding architect/professionals.
section 1603.1.4 wind design data:
the following information related to wind loads shall be shown, regardless of whether wind loads govern the design of the lateral force resisting system of the building:
5. components and cladding. the design wind pressures in terms of psf (kn/m2) to be used for the design of exterior component and cladding materials not specifically designed by the registered design professional
just what i needed - thanks-i wish "our" engineer would respond so quickly!
i generally do a little key plan with the roof areas and higher pressure areas indicated as well as having the base design loads in my general notes.
dik
@kdxbob
i could get in touch with you if you want to recommend/hire us.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
perpendicular roof wind pressures huangyhg 产品功能分析 0 2009-09-15 12:13 PM
massachusetts building code load combinations huangyhg 产品功能分析 0 2009-09-10 01:04 PM
load combination questionpoll huangyhg 产品功能分析 0 2009-09-10 11:01 AM
british wind loading codes huangyhg 产品功能分析 0 2009-09-07 05:19 PM
asce figure 6-10 wind loads huangyhg 产品功能分析 0 2009-09-07 01:22 PM


所有的时间均为北京时间。 现在的时间是 05:10 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多