hello all,
i am in the process of designing an 80' x 80' pre-fabricated metal building in florida. i was speaking with the architect today and he mentioned that when dealing with wind loading in a square building, the code allows the elimination of the increased wind loading at the end zones and i was supposed to just use the normal interior zone wind loading for the end frames.
i informed him that i was unaware of such a requirement and would look into it.i have looked at the ibc 2000, asce 7-98 and fbc 2001 building codes but can not find any such reference to a squre building and the elimination of end zone loading.
if anyone is aware of this requirement, i would appreciate if they could verify this requirement for me. also, could they please provide any code reference to support their argument or is this just a form of industry practice?.
thanks,
js.

i am not aware of this either. i would be interested in seeing where the architect obtained this info.
looking in the asce 7-98 pg 42-44. the length in not used to obtain the gcp. you use the effective wind area. i did not see any mention of that anomaly. i do not see how a 80'x75' or 80'x85' building would require endzone loading while a 80'x80' would not. i am under the impression that the endzone is loaded differently because of the air coming by the corner and off the roof creates a greater suction than in the middle of the building that only has air off the roof.
what code is specified for the project? i am not familiar with florida of if they have a local code that might address this.
the corner wind zones will still have to be considered on this square building. the florida building code, asce or ibc do not have any allowable reductions.
when the wind load is directed at the building and can't go through the building the air must go around. therefore, the corner will create higher corner negative wind loads.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
ibc wind exposure c definition - florida building code huangyhg 产品功能分析 0 2009-09-09 06:57 PM
ibc 1609.1.2 application huangyhg 产品功能分析 0 2009-09-09 06:37 PM
glazing in non-windbourne debris areas huangyhg 产品功能分析 0 2009-09-09 02:42 PM
effects of a load on sog and below grade huangyhg 产品功能分析 0 2009-09-08 09:45 PM
british wind loading codes huangyhg 产品功能分析 0 2009-09-07 05:19 PM


所有的时间均为北京时间。 现在的时间是 08:41 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多