默认 atlanta partial parking deck collapse

atlanta partial parking deck collapse
i haven't seen this posted yet. rather unfortunate for the contractor (same one as botanical garden walkway collapse)...they're actually "better" than most contractors i run across.
yeah, hardin's a pretty good contractor...certainly above average. noticed that a precast soffit beam popped out. could be connection deterioration, design, construction...who knows at this point.
i know it's a speculative generalisation, but i have never felt comfortable in these precast parking structures. there is not enough robustness in the connections or redundancy in the system for my liking. give me a steel framed or cast in place structure anytime.
hokie66...i agree. i've wondered if the traffic vibration would push a beam off its corbel/haunch. not much holding these things together.
i've done many precast, steel and reinforced concrete parkades and nary a problem, yet! the first one i did using 12" hollowcore about 30 years back just had an couple of floors added.
dik
i'm working on one right now.....
i'll be tossing and turning tonight.
clansman
if a builder has built a house for a man and has not made his work sound, and the house which he has built has fallen down and so caused the death of the householder, that builder shall be put to death." code of hammurabi, c.2040 b.c.fff">
i'm not saying they can't be built so they behave satisfactorily, and i am confident that you fellows will do your best, tossing and turning included, to make sure they are competent structures. but the first thing i think of when i hear of a parking structure collapse is "not another precast house of cards".
i am even less confident than hokie66 in this kind of structure. here it has been used not only in parking but multilevel supermarkets of the "we are the cheapest" type full of people and, locally, racks to the ceiling. yet till now, and even in spite of too small seats by any *** subjective*** standards, i am not aware of any notorious failure.
the same can't be said of bridges with standard to small seats, some have collapsed upon rotation of the foundation and column, or upon impact of a truck.
the lack of redundancy in a precast parking structure won't come in to play until a major seismic event or explosion.
the seating of the haunches are more than adequate for normal loading and the welded connections with the chord/diaphragm steel will hold the pieces together under loading.
when i think of a precast double-tee i would consider it better than an open web steel joist floor system which are used all the time for supermarkets.
problems with precasst dt systems - welded steel connections need to be maintained. flange reinforcing is wwr which may degrade without any visual sign. diaphragms may span great distances without lateral support (250 ft between shearwalls).
here's my suggestion to help everyone sleep a little better at night..."completely/strictly" follow the special inspections program (with a good/qualified testing firm on board essentially full time if possible) to help document the construction and so that you/designer are able to say it was built like it was designed. i have not seen the same urgency to follow si on precast as for steel (which is still lacking by the way). from my independent third party eyes, some of the precast field work is "scary" to say the least(basically iron worker mentality except with precast--you know what i mean if you've been around construction long enough)...all i'm going to say at this point.
been to that parking deck before...nothing out of the ordinary that i noticed (but wasn't looking for anything). and apparently pretty vacant of people at the time of collapse so maybe not traffic vibration. the parking deck only few years old.
and i really do hate to see the hardin folks wrapped up in this one...but it should be an eye opener to everyone as to what the rest of the construction really looks like.....(don't fool yourself--again from these independent eyes)
just an anecdote,
once i was asked to start design for some maintenance buildings holding some trucks and in whatever the way, i came with some solution that had precast l and inverted t beams; i did preliminary checks and determined the sections had to be truly massive and of 60 mpa characteristic strength or near 9 ksi. i scrapped the idea.
10 years passed and my job then (last year's) went through a design of akin loads and structural system, then i found there was at town a glistening (wholly new facilities) firm making those gross beams at such 60 mpa strength and seemed to have enough success to stay working.
simply, that one doesn't want to do something is not warranty of that this won't be done by another. nor a warrant of that one is right on using it or the contrary.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
assuming metal roof deck rigid diaphragm huangyhg 产品功能分析 0 2009-09-07 01:39 PM
analyzing parking garage for large crowd of people huangyhg 产品功能分析 0 2009-09-07 11:42 AM
30mpa parking garage concrete slab vs. 35mpa huangyhg 产品功能分析 0 2009-09-07 08:39 AM
nform deck as diaphragm - er repor huangyhg 产品功能分析 0 2009-09-06 10:22 PM


所有的时间均为北京时间。 现在的时间是 08:37 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多