几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量  


返回   几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量 » Norm Space: Product Automatic Standards - 范数空间:产品自动化标准 » National Standards » American standards
用户名
密码
注册 帮助 会员 日历 银行 搜索 今日新帖 标记论坛为已读


 
 
主题工具 搜索本主题 显示模式
旧 2009-05-04, 11:01 AM   #1
yang686526
高级会员
 
注册日期: 06-11
帖子: 14579
精华: 1
现金: 224494 标准币
资产: 234494 标准币
yang686526 向着好的方向发展
默认 【转帖】undimensioned tolerance

undimensioned tolerance
i have a drawing that states the following :
interpret drawing per asmy14.100-200, dimensions and tolerances per asme y14.5m.
in the drawing all the dimensions in the drawing are untoleranced. do i interpret these as basic dimensions?
find a job or post a job opening
there should be a tolerance block somewhere on the drawing format. that, or a note stating that untoleranced dimensions are basic.
it's not uncommon to place that in a note "all untoleranced dimensions are basic" but you must also account for all permissible geometric variations. this can be done by having a global note stating a general surface profile. i've seen this on complex castings.
best regards,
heckler
sr. mechanical engineer
sw2005 sp 5.0 & pro/e 2001
dell precision 370
p4 3.6 ghz, 1gb ram
xp pro sp2.0
nivida quadro fx 1400
o
_`\(,_
(_)/ (_)
"coming together is a beginning, staying together is progress, and working together is success." - henry ford

we also use "all dimensions are reference"
we do this if we buy a part as is and just want some dimensions for information purposes. it allows a receiving inspector to verify that we have a 1/4-20 x 1 inch long bolt, but he doesn't have to do a layout on the part.
thanks to all that replied.
it turns out i was not given all the information. i only recieved the drawing not the specification sheet with the tolerance block.
seems a little queer that someone would put a tolerance block on a separate specification sheet, instead of on the drawing (where it would actually be useful).
sunthorn-
maybe this is pulling hairs, but the drawing should simply say "interpret drawing per asme y14.100m." since y14.100m invokes y14.5m, then it's redundant to invoke them both. also i believe that y14.100m says that the year of the standard should be left out of the callout (you might want to confirm this!).
tunalover
yang686526离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
【转帖】position tolerance of the opening which is in distance from yang686526 American standards 0 2009-04-29 09:20 PM
【转帖】pattern locating tolerance zone shape yang686526 American standards 0 2009-04-29 09:13 PM
【转帖】asme - where to star yang686526 American standards 0 2009-04-29 07:28 PM
【转帖】calculating positional tolerance yang686526 American standards 0 2009-04-29 06:43 PM