默认 what concrete strength to assume

what concrete strength to assume
when we only have a mix design indicating the ratio of components, such as 1:2:3 or 1:2:4 and no further information? i intend to require material testing of the existing structure to confirm, but what should i assume to start with?
i have typically taken 1:2:3 mix as being between 2500 and 3500 psi, and testing has usually found something in this range, however this project is one a tight deadline and i'm just a bit worried that i've been "getting lucky".
any guidance anyone would care to offer? the structure in this case is a reinforced concrete bridge built in late 1930s in rural new zealand.
thanks,
ys
b.eng (carleton)
working in new zealand, thinking of my snow covered home...

1930's rural concrete batching anwhere can be extremely variable. even in the 1940's somce was a combination of weight (94# bags of cement) and approximate volume catching of aggregates. wet sand can bulk, cusing a higher than normal material content, that can give higher strngths.
i would keep expectations low in the 2500 to 3000 psi range, but would not be surprised to see cores over 4000 psi if all the batching variables, placement methods and inplace curing was good. - time does wonders on some concrete.
a bridge may have had better ot tighter tighter controls, but can only go so far if there are not options.
only testing will determine what kind of animal your have to deal with. on a lighter note, are there wambats in new zealand?
if it were me, i wouldn't assume anything...or just assume "something" with a wide range simply for the sake of assuming realizing that you will probably not be correct. it doesn't take long to core and break...
this might help (the website has a lot of free documentation too that might help). just keep in mind that you're dealing with 70+ year old concrete.
i don't have a copy in front of me, but the only thing i can think of off the top of my head is that you look at the w/c ratio for that mixture and see what expected f'c you have according to the pca concrete mixture design book. i'd bump up the water content to account for moisture in the sand. by how much? use some judgment for that.
could you do some "non-destructive" testing to get a ballpark?
thanks for the advice all; i'm not too concerned regarding the concrete compressive strength for the beams as the steel strength is much more critical. the compressive strength is critical for the piles, and i can test this as there are original pile cut-offs still on site (surprising after 70 odd years, but also very convenient).
i was hoping someone would have a resource for an indication regarding proportionate design to reliable assumed concrete strength, even though i'm experienced enough to know better than to think a design-reliable assumption is possible not knowing w/c ratio or anything about the aggregates (both fine and course).
i own a copy of the mix design text from cpca, but unfortunately it's in canada...
oh, and no, new zealand does not have wombats. that's australia.
cheers all,
i'll update when i know the core results,
ys
b.eng (carleton)
working in new zealand, thinking of my snow covered home...
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete sampling guidlines huangyhg 产品功能分析 0 2009-09-08 12:34 PM
concrete mix= reinfocing for exterior composit deck huangyhg 产品功能分析 0 2009-09-08 12:19 PM
concrete compressive strength huangyhg 产品功能分析 0 2009-09-08 11:53 AM
chapter 4 preliminary design properties of concrete huangyhg 产品功能分析 0 2009-09-07 11:23 PM
28 day vs. 56 day concrete breaks huangyhg 产品功能分析 0 2009-09-07 08:34 AM


所有的时间均为北京时间。 现在的时间是 05:59 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多