use of someone else's wall
perhaps the folks on this forum can give some insight regarding something that i observed in one of my numerous trips to new york city. i recently observed a new building under construction while walking down a street. i noticed that the new building was a steel framed structure with interior columns. at the outside perimeter, the steel beams were being anchored into the walls of the adjoining buildings. this seems a little weird to me. i am wondering what happens when the owners of the adjoining buildings decide to knock them down and put up something newer. it appears to me that demolition of the adjoining buildings would cause a partial collapse of the middle building. once the middle building is completed, no one would be able to tell visually that the adjoining building's walls were utilized to hold up the middle building. the building in question is about 5 stories high with a footprint of about 40' x 40'. all three buildings described fill the entire lots that they are upon. i saw another building being constructed in this manner about 15 years ago and i thought it was weird them. seeing this newer one a couple of weeks ago stirred up those old doubts. what do the other, more experienced than me, folks on this forum think?
find a job or post a job opening
possibly what you saw was "soil/rock" nailing where the anchored wall you saw was placed to underpin the existing structure so that the existing building wouldn't undergo excessive settlement or tilting during the excavation of the new building. the building going up would have it's own basement wall. it may look like what you are saying but i very very much doubt it.
you probably were looking at a party wall, a wall owned by both adjoining properties. the property line runs down the center of this wall. therefore, one owner can not tear down the wall if another also owns it.
peinc,
i don't think that the particular wall that i saw was a party wall. the remnant of the original wall for the middle building was present, but had been torn down almost to ground level. you could see the holes for the joists in it. most of the new steel was above this wall portion and appeared to be attached to the walls of the adjoining buildings.
sounds like the old floor joists were worthless, and it was decided to completely replace all the floors, and leave the brick bearing walls to use again.
situations like that are common in nyc. alot of the turn of the century building floors just cant support office or retail live loads. it is often easier to replace the whole floor than to try remedial work.
eddyc,
very odd. i've never seen someone tie a new building into an existing wall that is totally on someone else's property. i can't imagine how that could be allowed unless the same person owned both buildings.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
retaining wall near a river bank huangyhg 产品功能分析 0 2009-09-15 06:39 PM
retaining wall failure huangyhg 产品功能分析 0 2009-09-15 06:38 PM
in enercalc masonry wall design, what is parapet heigh huangyhg 产品功能分析 0 2009-09-09 07:17 PM
foundation wall 40 feet below grade huangyhg 产品功能分析 0 2009-09-09 01:38 PM
concrete basement wall design huangyhg 产品功能分析 0 2009-09-08 11:39 AM


所有的时间均为北京时间。 现在的时间是 03:58 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多