默认 spacing isolation pads under a floating floor

spacing isolation pads under a floating floor
hi
i am trying to determine the minimum thickness of particle board to lay on top of an arrangement of discrete elastomeric vibration isolation pads in a floating floor construction.
i need to determine the most appropriate pad spacing for different types of board. the board is essentially being used as a shuttering to prevent concrete/screed from getting between the isolation pads when it is poured. the board must therefore not deflect significantly between the pads.
the deflection of the pads will vary depending on the type of material that we use. in the case i am dealing with currently the pads are initially 10mm thick with a deflection under load of a little over 1mm.
can anyone suggest how i might approach this problem?
many thanks,
mark
check the tables in ibc chapter 2304. they give you a starting point anyhow. since you are only using it as a form, the loads shown can be greatly exceeded.
can you consider using a steel deck as the form?
thanks for that. i'll have a look at the codes once i can track down a copy.
the floor is intended for use in domestic dwellings. the original design was a full area resilient mat and the spec of the board was not an issue. unfortunately, putting a steel deck is not a possibility at the moment.
we need something sufficiently stiff that is relatively cheap and will have limited impact on the height of the construction.
mark
a couple of thoughts:
the "floating floor" design you are describing sounds very much like the design used for some gym floor installations. the ones i've see use one sheet of 3/4" thick plywood or two sheets of 1/2" plywood laid 90 degress to each other over the elastomeric pads. the pads are about 2-1/2" square and 1/4" thick spaced about 12" on center. the strip flooring is then placed over the plywood. you might search the web for gym flooring manufacturers and check with them.
one caution to keep in mind with particle board - it absorbs water very quickly, swells and then quickly starts to deteriorate, much faster than plywood.
why a floating floor
is not a rubberized compound block system an option
just guessing as there is little detail
but i appreciate some designs cannot take these
assuming you need vibration dampened forms
mikehydrophys
mdshydroplane
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
floor loading question huangyhg 产品功能分析 0 2009-09-09 12:48 PM
floor level huangyhg 产品功能分析 0 2009-09-09 12:46 PM
floor joist spacing huangyhg 产品功能分析 0 2009-09-09 12:44 PM
anchor bolts spacing basement walls huangyhg 产品功能分析 0 2009-09-07 11:53 AM
allowable floor deflections versus workmanship standares huangyhg 产品功能分析 0 2009-09-07 10:58 AM


所有的时间均为北京时间。 现在的时间是 06:26 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多