默认 soil bearing capacity from n-values of spt for design purpos

soil bearing capacity from n-values of spt for design purpos
is there any reference material available that gives values of soil bearing capacity for various soil foundation types (e.g. compacted sand and gravel, etc) using corresponding n-values obtained from standard penetration tests?
check out our whitepaper library.
artnkman
yes you can refer to the book 'foundation analysis and design' by j.e.bowles by mcgraw-hill publications.particularly you can ref to articles 4.10 and 3.7(i am refering to iv edition & v edition is out)
as soil material under foundation or any where is not a homogeneous one itt is difficult to define exactly the properties of soil wihout making soil sampling and experimental studies for each idividual case, geotechnic studies shuld be carried out on the strata before defining the type of foundation that will be suitable, in some soils sometimes spt is giving an idea about the stiffness of the soil and the scientists creat a relation between nos. of blows and bearing capacit y but this value of b/c should not be taken into consideraton in design without taking the other factors, that is not every thing about soil .
you will find several books which provide bearing capacity correlated to spt values. these should be taken only as references or 'base values'. if a geotechnical engineer was hired to do a soils investigation he should be able to provide you with this estimate. if there was no geotechnical engg. you could hire one for a nominal price and have him provide you with an estimate based on existing data.
just out of interest, if you provide me with the relevant data i could see what i could do. ( i have some geotech. experience)
you need to contact a geotech that did the testing of the soil. the n values are good as a rule of thumb, however some soils are sensative to moisture changes and other soils are sensitive to re molding. caution is the watch word
if it's vertical bearing pressure you're looking for, then i would agree with those respondants who approach this conversion with caution, especially when long term settlement is a major consideration.
however, if it's lateral passive pressure you need (such as lateral loads on direct buried poles), then you might try these conversion estimates:
for sand, phi angle = 27.5 + n/4. from phi,of course, you can get the rankine value.
for clay, c = n/7.5 in ksf.
in both cases, always consider the soil in a submerged condition for applying minimum density (well, maybe not in arizona or west texas!).
and last but not least, run it by a qualified geotech engineer and use a sf of not less than 2.0.
william ford
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
increase presumptive soil bearing ubcibc huangyhg 产品功能分析 0 2009-09-09 07:24 PM
ibc 06 table 1804.2 bearing capacities allow. or gross huangyhg 产品功能分析 0 2009-09-09 06:36 PM
bearing capacitypressure of existing asphal huangyhg 产品功能分析 0 2009-09-07 03:15 PM
bearing capacity of thru-bolts on brick huangyhg 产品功能分析 0 2009-09-07 03:14 PM
allowable bearing capacity huangyhg 产品功能分析 0 2009-09-07 10:51 AM


所有的时间均为北京时间。 现在的时间是 12:30 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多