snow drifting around horizontal pipe on roof
i am currently analyzing the feasibility of installing a 40" diameter pipe horizontally, along an existing monosloped roof that is 160 feet long. this pipe is to be installed about 130 down from the high point of this roof that is sloped 1:12 (the roof at this point is about 10.83' lower (in elevation) than the high point. once this pipe is installed, it should project about 4.5' from the roof level (to the top of pipe). my questions are as follows:
1) i know that i have to consider windward drifting, but should i also consider leeward drifting at the same time? the flat snow loading is about 1.5' high and the windward drifting is just over 3' high. could drifting on this monosloped roof cause the windward pocket to fill in and cause additional leeward drifting on the other side. should account for the leeward drifting the same time as the windward drifting?
2) if i can convince the client to reposition the pipe only 80 feet away from the high point (center of the roof), the top of snow drift should be about 6" below the top of pipe. would it be feasible to neglect any possible leeward drifting in this case?
3) if i want to avoid snow drifting around this pipe all together, how high would i need to set the pipe? i would guess that i would need to set the bottom of pipe about 6" higher than any possible snow drifting height. (in other words, about 5' high to the underside of this pipe.)
thanks in advance for all your input!
find a job or post a job opening
i would likely consider 15 psf per ft of height extending approximately 8' to 10' on either side of the pipe, without more correct information.
dik
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
snow drift with parapet at high roof huangyhg 产品功能分析 0 2009-09-16 12:01 AM
snow drift on sloped roof huangyhg 产品功能分析 0 2009-09-15 11:58 PM
snow drift flat roof adjacent to gable huangyhg 产品功能分析 0 2009-09-15 11:55 PM
perpendicular roof wind pressures huangyhg 产品功能分析 0 2009-09-15 12:13 PM
horizontal snow pressures huangyhg 产品功能分析 0 2009-09-09 05:05 PM


所有的时间均为北京时间。 现在的时间是 01:25 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多