默认 seated beam connection

seated beam connection
hi everyone,
i'm designing a seated connection for a tubular beam connecting to a tubular column. i find that the ways i've seen to establish the required bearing length (n) are a little unclear. since n is an important property for determining the thickness of the angle which will be used as the seat and the excentricity of the load, i was wondering if anyone has a good rule of thumb or precise way of calculating n.
thanks in advance
steven
quebec, canada
1. you may fix the point of reaction by welding a plate...at least at one end.
2. a procedure to determine eccentricity of the reaction but for double tee loading is given in ensidesa manual tomo ii** p. 7.7 3-1. the thing is that nor web thickness nor to end of fillet (required) dimensions are available for pipe built trusses, for tubes some adaptation maybe made to some risk. the manual also gives tables for spanish shapes etc.
3. also for double tee loading i have a mcad worksheet made and think posted at the collaboratory, if you can't download, i can send it.
4. work in the descent must be minimum, so the reaction at end will move inwards till the deformation work is minimum and still satisfies equilibrium. since the reaction is constant, and the deflection will be lesser the more closer it is to the top welded end of tha angle, any support length that satisfy the capacity of passing in bearing to the truss itself should be a good guess of your supported length, hence eccentricity known. so your problem resumes in guessing what length of lower chord you need supported to properly take the reaction. this can be even ascertained by fem, or simply assumed.
5. the design guide for hollow structural section connections by packer and henderson of your cisc have at least indications for end connection for hss ... that may be late to implement. in any case worth to have and look at.
hi ishvaaag,
for your 2nd point, i stayed conservative and used the thickness as the web and the end of fillet.
what i did, also, was determine the bearing length using the load which was the maximum the tube was going to have to hold:
max load = 1.1*0.9*web thickness*(n+2k)*fy
solving for n.
i would like to know the web address for your mcad worksheet if possible.
thanks for responding ishvaaag
have a good one.
so if you have a good guess of the required supported length problem solved as per point 4 above.
site is
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
question regarding floor support beam installation huangyhg 产品功能分析 0 2009-09-15 03:58 PM
odd beam to column connection 9steel0 huangyhg 产品功能分析 0 2009-09-10 04:54 PM
cross beam bolted connection huangyhg 产品功能分析 0 2009-09-08 03:55 PM
cantilever steel beam at column huangyhg 产品功能分析 0 2009-09-07 10:40 PM
12 x 6.5x 38 thick x 41 residential basement i-beam con huangyhg 产品功能分析 0 2009-09-06 10:30 PM


所有的时间均为北京时间。 现在的时间是 09:13 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多