默认 roof water proofing

roof water proofing
a flat roof of building is leaking. buidling is old so do not want to place some heavy water proofing material on it.
can you recommend some good material. also slab is depressed at middle (may be 3 inches). is there some thing we can place thicker in middle and thins out to ends to mock a sloping roof.
have you considered installing a new steel sloped roof on above it the flat roof? i am seeing this more often, the patching seems to only work temporarily on flat roofs.
plainsboro-
what caused the low spot?
if you can tear off the old roof, consider using tapered insulation or a non-structural self leveling compound to fill in the low spot.
if the roof structure is underdesigned there are several types of unballasted single ply membranes available that you could use to re-roof and keep your dead load down.
what kind of roof deck do you have? does the existing roof pitch and drain properly, other than the low spot?
regards.
sarnafil is a good long life covering, but you will have to address the low spot. assuming that you find the roof at that point structurally sound, you may want to add an additional roof drain at that point.
when you have lemons, make lemonade.
plainsboro...as said, check the reason for the middle deflection. if structurally ok, then you can use lightweight insulating concrete (lwic) or tapered insulation (more expensive and requires more installation skill) to provide the slope you want, then put most any type of membrane on top of that (remove existing membrane). my preference is a modified bitumen membrane with granular surfacing.
lwic and membrane will weigh about 8 to 10 psf for reasonable thicknesses, but can easily jump up to 12 to 14 psf if the lwic gets too thick. tapered insulation and membrane will come in at 6 to 8 psf.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
roof drain restrictors huangyhg 产品功能分析 0 2009-09-15 07:22 PM
ponding huangyhg 产品功能分析 0 2009-09-15 01:29 PM
perpendicular roof wind pressures huangyhg 产品功能分析 0 2009-09-15 12:13 PM
low slope roof construction huangyhg 产品功能分析 0 2009-09-10 11:50 AM
flat roof repairs huangyhg 产品功能分析 0 2009-09-09 12:23 PM


所有的时间均为北京时间。 现在的时间是 12:21 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多