默认 rain loads

rain loads
sloped or not, each segment of the roof shall be capable to carry the loading created due to blockage of the primary roof drainage system of that segment plus the load caused by water that rises above the inlet of the secondary drainage system at its design flow rate. the event that shall be considered is an intense short-duration rainfall. this is defined differently by different codes. it is approximately equivalent to 1-hour duration rainfall with a 100-year return period. check the governing code for your project.

nuty,
amokhta's reply covers the subject very well. let me just add that if the roof segment has a slope steeper than 1/4 inch per foot toward points of free drainage, we do not have to check the structural strength of the roof for ponding of rainwater.
the design of the roof drains and piping is based on the rain hourly rate specified by the applicable code. structurally, we design the roof for the water accumulated considering the deflection of the roof system.
aef
in flat roofs, put ample spill-overs in the parapet to limit rain load upon clogging of the primary sumps.
casiooreo9 (visitor)19 apr 02 0:10
a roof with a parapet will have roof drains and overflows - an overflow typically extends 2" above the low part of the roof (not the roof drain basin) - this means there could possibly be 2" of water at the deep end and based on the roof slope the weight is determined....check with the plumbing codes
casioore09
i agree in 2" of water downstream be very much nice a load. where i live it rains scarcely (220 mm a year) and you would be annoyed of the general miscare with which these things are...not made. furthermore there are the inner patios where to produce the spill-over would mean plumbing, yes, this even less done than what other.
fortunately the total load here is unlikely to go as high as to extenuate the structure and in fact these failures here are mostly unseen. underpass or cellar flooding is more common.
by the way i had 20 years ago the opportunity to load with 20 cm of water a rc 25 or 30 cm deep beams/25 or 30 cm deep rc joists (half) roof in a condominium in construction and the structure made to the spanish code eh-80 passed the test without any noticeable movement.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
new york 2007 code snow loads - reduced huangyhg 产品功能分析 0 2009-09-10 04:23 PM
intl bldg code wind loads huangyhg 产品功能分析 0 2009-09-09 09:19 PM
fea on conrete slab - use real loads or factored loads huangyhg 产品功能分析 0 2009-09-09 11:24 AM
crane loads in staad pro huangyhg 产品功能分析 0 2009-09-08 02:35 PM
are asce 7-02 wind loads ultimate or service level huangyhg 产品功能分析 0 2009-09-07 12:46 PM


所有的时间均为北京时间。 现在的时间是 07:29 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多