metal roof repair options
we are searching for repair options to our 28 yr old r-panel metal roof. my preference is to remove and replace with a standing seam system. however, the folks who write the checks want less expensive alternatives.
we're doing a structural analysis to determine if the frame will support a standing seam overlay. foot traffic precludes a spray foam system.
i've come across a system that involves spraying a synthetic rubber coating over the top of the existing roof (after prepping it). it seems like a good theory and i wanted to know if anyone had any experience with these sorts of systems. the vendor, of course, promises the world.
or, if anyone has any other suggestions to keep the rain out, i would like to hear them.
regards,
jc

basically the problem boils down to doing a life cycle cost analysis. my gut feeling is that over the next twenty years, the retrofit, standing seam roof is the best bet, but not the cheapest first cost. the trouble with the "exposed fastener" type metal roofs is the tempature changes that the roof goes through during the course of year. the screws work loose and punchture the spray-on membranes.
whoever you pick to do the roof, be sure to get lots of references and check the references. i recently did a damage investigation of a standing seam roof retrofit where the contractor installing the roof did not follow the manufacturer's installation instructions. the roof was fine for about four years, then just the right wind storm from just the right direction blew it off. the clips used for the roof were fine, but the installer only put one screw in instead of the two required. inspection, inspection!
good luck.
jcovey,
we installed a rubber membrane over two of our roof sections five years ago and are very happy with it.
the original metal was a standing seam type and the first step was to place styrofoam panels between the ribs. they then added another layer of foam across the entire roof after which the membrane was placed and glued.
we have tried the sprayed material and were not happy with it. we have tried brushed asphalt coatings and have not been happy with them.
in the past much of our foot traffic was due to breaking up ice dams. with the extra insulation and continuous covering, we no longer have the dams.
we have one section of roof under membrane that has lasted over 20 years (installed in '78) and is still looking good.
griffy
jheidt, griffy,
thank you for your input. j, i've got the same opinions as you regarding the fastener problems as well as the standing seam retrofit being the best option. we are enlisting the services of a roofing consultant to help with preparing the design and bidding documents and to monitor and inspect the installation of whatever system we select.
griffy, i'm glad to hear your feedback on the spray on system. i didn't mention it, but we're considering the membrane option, too. factory mutual is our insurance carrier and they get a funny look on their face when a membrane roof is mentioned. i don't know if it's the wind uplift concerns or the additional decking required to lay the membrane over the ribs. i've also been told that the membrane roofs are incredibly slippery when wet and i don't want to create a safety hazard for my guys who are performing maintenance to rooftop equipment.
again, thanks,
jc
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
metal bldg drift w brick veneer huangyhg 产品功能分析 0 2009-09-10 01:34 PM
low slope roof construction huangyhg 产品功能分析 0 2009-09-10 11:50 AM
flat roof repairs huangyhg 产品功能分析 0 2009-09-09 12:23 PM
flat roof repair huangyhg 产品功能分析 0 2009-09-09 12:23 PM
directions on a flat roof repair huangyhg 产品功能分析 0 2009-09-08 06:54 PM


所有的时间均为北京时间。 现在的时间是 11:29 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多