默认 liquid storage tank sloshing weigh

liquid storage tank "sloshing" weight
in asce 7-05 section 15.7.6, it lists a wc variable which is defined as the portion of the liquid weight sloshing. can anyone offer any guidance on how this is calculated?
see awwa d100-05.
per eq. 13-26, wc = 0.230(d/h) tanh(3.67h/d) wt, where wt is the total liquid weight.
don't expect awwa d100-05 (or api-650 add. 4) and asce 7 to be consistent with each other- they're not exactly in sync with each other.
also, the api 650 standard gives criteria and calculation methods for earthquake sloshing in tanks.
the awwa equation makes sense, but what's got me puzzled with asce 7-05 is that they say the "portion of the liquid", whereas awwa uses the total liquid. if the total liquid weight is used with asce, then the total liquid weight is being used twice to determine the base shear since the impulsive force, wi, also includes the liquid weight.
by the way, this is not being used to design the tank. only as a check of the vendors loads supplied for foundation design.
that equation above gives you the convective portion of the liquid. wt is the total liquid weight, wc is not.
wi is the impulsive portion of the liquid, given by a different formula, and is not the total liquid weight, either.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
drains for secondary storage tank huangyhg 产品功能分析 0 2009-09-08 07:37 PM
consider an oil storage tank 30 me huangyhg 产品功能分析 0 2009-09-08 01:21 PM
baffle plate thickness for a rectangle tank huangyhg 产品功能分析 0 2009-09-07 02:09 PM
applying eq forces on liquid containing tank huangyhg 产品功能分析 0 2009-09-07 12:35 PM
8000gal water tank foundation design huangyhg 产品功能分析 0 2009-09-07 08:59 AM


所有的时间均为北京时间。 现在的时间是 02:11 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多