concrete slab and wood piles
i am designing a 3-story beach house. my question is the second and third story are being supported by piles that are embedded more than 20' deep in sand. the first floor garage will consist of reinforced concrete slab on grade foundation. question: what type of material could be used between the wood piles and the concrete slab to allow for expansion or contraction?
check out our whitepaper library.
longitudinally, wood is generally dimensionally stable. usually with wood piles, i use a concrete cap to support the slab.
dik
i guess since the concrete slab will be poured around the columns, do i need something like an expansion joint around the columns?
sounds like you are concerned about the radial expansion of the timber piles at the point where they penetrate the slab on grade. i suggest warping them with typical expansion joint material such as this
i vote for pouring the concrete around the piles with no gap at all. this will give you a fixed connection at the base and really help in stiffening up the building. a pile embedded in the sand is not really a fixed base. just make sure you have enough concrete and reinforcement around the piles.
the concrete is going to crack, so reinforce it to control them. i am not even sure if you would prevent any additional cracks anyway by providing a gap. i think the added stiffness you will give the building is more important anyway. a lot of beach houses i have been in will make you sea sick if there is a stiff wind.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete mix= reinfocing for exterior composit deck huangyhg 产品功能分析 0 2009-09-08 12:19 PM
concrete beam repair huangyhg 产品功能分析 0 2009-09-08 11:41 AM
concrete balcony supported by the threaded rod design huangyhg 产品功能分析 0 2009-09-08 11:38 AM
blinding concrete - specified grade huangyhg 产品功能分析 0 2009-09-07 03:56 PM
12 x 6.5x 38 thick x 41 residential basement i-beam con huangyhg 产品功能分析 0 2009-09-06 10:30 PM


所有的时间均为北京时间。 现在的时间是 01:09 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多