几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量  


返回   几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量 » 三维空间:产品设计或CAX软件使用 » CAD设计 » 产品功能分析
用户名
密码
注册 帮助 会员 日历 银行 搜索 今日新帖 标记论坛为已读


 
 
主题工具 搜索本主题 显示模式
旧 2009-09-08, 12:11 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 concrete foundation

concrete foundation
someone i know poured an 8' heigh foundation and now wants to go to nine feet. any suggestions or recomendations on how to properly bond/secure the new 1'concrete section to the existing foundation? any reference material covering this problem?
thanks,
john
check out our whitepaper library.
here is what i have seen some guys doing.
you break the existing concrete in the area where you are going to add more concrete. you leave the reinforcement intact. clean up. then you add reinforcement and tie them to the existing. finally you pour new concrete over.
this is probably easier than using chemically bonded rebars.
one opinion from me. good luck.
just to make sure you dont miss this one:
"happycamper" posted a question joining new concrete to old in the concrete engineering forum, and ron,jae, qshake etc great guys did a very good job answering that.
visit there too as you wait for better responses to your specific question
what is the foundation meant for?
are the rebars sticking out? will u have enough development lenghths/laps for fixing reinforcement.
if its yes, than u can roughen the area of concrete that is to receive new concrete by say 25mm to 50mm. clean by sand blasting or wire brush. the surface should be dry and free of standing water. apply sikadur 32 ( sika product ) by brush and place fresh concrete while it is still tacky.
riz
yeah riz
great idea. never used sika 32 before, a nice new adventure.
seems a good solution if you have enough reinforcement sticking out from existing part. i will definitely use that.
i am just curious, what shall we do in case of no reinfocement sticking out, since in most cases, especially in metal structures, you dont have reinforcement projecting out at a finished level.
equally interested.
ijr
well, i agree with the first answer to your post however, it all depends on the spacing of the existing re-bars. if the re-bars provided are not adequate, spacing and size, then the best solution would be to drill the existing wall place a re-bar in the drilled holes with proper length and then form and pour the new concrete section. i would check the height of unballanced fill to make sure it is not exceeding the design of the wall. make sure that the holes in the existing wall are clean and epoxy them after the re-bar placement.
gita
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete failure along steel surface huangyhg 产品功能分析 0 2009-09-08 12:05 PM
concrete corrosion in partial saturated condition huangyhg 产品功能分析 0 2009-09-08 11:54 AM
chapter 4 preliminary design properties of concrete huangyhg 产品功能分析 0 2009-09-07 11:23 PM
building on old concrete basement foundation huangyhg 产品功能分析 0 2009-09-07 05:42 PM
blinding concrete - specified grade huangyhg 产品功能分析 0 2009-09-07 03:56 PM