几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量  


返回   几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量 » 三维空间:产品设计或CAX软件使用 » CMM检测 » PC-DMIS
用户名
密码
注册 帮助 会员 日历 银行 搜索 今日新帖 标记论坛为已读


回复
 
主题工具 搜索本主题 显示模式
旧 2009-03-31, 10:59 PM   #1
cad13992
初级会员
 
注册日期: 09-03
帖子: 13
精华: 0
现金: 189 标准币
资产: 189 标准币
cad13992 向着好的方向发展
默认 【转帖】runoutx2 = concentricity right?

Roughly speaking: runoutx2 = concentricity right?


Example. round part. I am chucking on the OD checking the runout of the ID

I get .0008 so the concent. roughly .0015?
cad13992离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
旧 2009-03-31, 11:01 PM   #2
cad13992
初级会员
 
注册日期: 09-03
帖子: 13
精华: 0
现金: 189 标准币
资产: 189 标准币
cad13992 向着好的方向发展
默认 回复: 【转帖】runoutx2 = concentricity right?

Concentricity:

The first feature must be a sphere (3D concentricity) or a slot, cylinder, cone, or circle
(2D concentricity). The second feature is used as a datum feature and must be a
cylinder, cone, line, or circle. If there is no datum, the origin and z vector of the
current active alignment are used for the datum.
If the first feature is a slot, cylinder, cone, or circle, the perpendicular distance from
the centroid of the feature to the datum feature’s axis is calculated. The 2D concentricity is twice this value.
If the first feature is a sphere, the 3D concentricity is calculated as twice the 3D
distance of the sphere’s centroid from the datum centroid (or active alignment origin
if there is no datum).
Starting with V40, Concentricity dimensions can be specified using feature control
frames similar to the callouts on drawings. The user must first define which feature is
to be used as a datum by assigning datum letters A, B, C, etc to the datum features.

Run-out:

The runout dimension determines the runout of the first feature with respect to the
second feature (i.e., the second feature becomes the datum feature). If only one
feature is selected, the origin of the current active alignment and the workplane
vector define the datum feature. The text in the Edit window for the datum feature
will read "THE ORIGIN".
This option works for circles, cones, cylinders, spheres, and planes. This
dimension type is considered one sided, meaning a single positive value tolerance
is applied.
The runout for circles, cones, and cylinders is the difference between the max and
min radial deviation of the measure points from the datum axis. The runout for
spheres is the difference between the max and min radial deviation of the measure
points from the datum origin. The radial deviation of circles, cylinders and
spheres is based on the measured radius of the feature. The radial deviation of
cones is based on the radius at the cone height of each measure point using the
measured angle of the cone.
The runout for planes is the difference between the max and min deviation of the
measure points from the plane formed by the feature plane’s measured centroid
and the datum vector.
For cylinders, cones, spheres and planes, the reported runout is the total runout.
For circles, the reported runout is circular runout.
cad13992离线中   回复时引用此帖
旧 2009-04-01, 01:32 PM   #3
cad13992
初级会员
 
注册日期: 09-03
帖子: 13
精华: 0
现金: 189 标准币
资产: 189 标准币
cad13992 向着好的方向发展
默认 回复: 【转帖】runoutx2 = concentricity right?

got this from GDT GUYS fourm (aerospace)

Concentricity is categorized as a tolerance of location, not form. However, surface variations of the controlled diameter can have a direct impact on the end result because a concentricity tolerance invokes a requirement which is much different than what most people realize.

When most people see a concentricity tolerance applied, they interpret the callout just as though it were a positional tolerance. In fact, many people think that concentricity is just another way of specifying position. But, in reality, concentricity is much different.

In ASME Y14.5M-1994, concentricity is defined as “the condition where the median points of all diametrically opposed elements of a figure of revolution (or correspondingly-located elements of two or more radially-disposed features) are congruent with the axis (or center point) of a datum feature.”
To verify "all the median points of all diametrically opposed elements" would require an extensive and time-consuming analysis of the surface in relation to the datum axis or point. Variations and irregularities in the surface will provide a different derived median point at each location measured, resulting in a "cloud" of derived points, all of which must lie within the specified concentricity tolerance zone. If even one of these median points lies outside of this zone, the part is rejected.

I have been working with for a lot of years, and I have never run in to a design situation where I was really interested in knowing where "all the median points of all diametrically opposed elements" resided on a part feature. I have always found that, for coaxial features, the design interest is in controlling either:
(a) the axis of the actual mating envelope to the datum axis,
or
(b) the surface location to the datum axis

Control of the axis location is usually applied when the primary design consideration is location of the feature to assure fit or assembly with a mating part, such as with a counterbored hole, shoulder bolt, etc. Ususally this is accomplished using a positional tolerance; not concentricity.

Control of the surface location is usually applied when the primary design consideration is distribution of the surface about a common center and is usually applied for parts that rotate, such as a pully or drive shaft. Control is accomplished using either a runout tolerance (circular or total) or a profile tolerance; but not concentricity.

In earlier versions of the Y14.5M standard, there was a statement that said that concentricity was used to control dynamic balance of a rotating part. But, they have since removed that statement because there are many factors other than median point distribution that contribute to proper dynamic balance.(such as distribution of material density) In fact, ASME Y14.5M-1994 doesn't provide any clue to the user as where concentricity should be used and even recommends that either a runout or positional tolerance be used instead of concentricity.

Concentricity is not well understood by all, it is expensive and time consuming when it is properly verified, it doesn't provide a control which logically supports most design cnsiderations and the defining industry standard even recommends that you use another type of control. This is pretty compelling evidence to stay away from using a concentricity tolerance if you ask me.
cad13992离线中   回复时引用此帖
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题