默认 waterstops

waterstops
i have a below grade covered tank. the water table is a few feet below the bottom of the slab so leakage into the slab is not a huge concern. the only real concern is during a floor or heavy rain.
at a minimum, i am going to spec ribbed waterstops all around the perimeter between the slab and the walls.
i have done some reading, but i can't find anything that talks about what size i should spec the waterstops. and there seems to be mixed reviews about whether waterstops are need are construction joints of the tank.
does anyone have any recommendations for waterstop sizing and whether they are needed at the wall construction joints? are they needed at the mat slab construction joints?
thanks

find a job or post a job opening
use 6 inch wide by 3/8 inch thick, non tapered waterstop for all construction joints. greenstreak model #679(
have you considered using bentonite, such as cetco waterstop-rx?
i use 6" pvc for non-movement joints and 9" for expansion joints (with center bulbs). i also put base seals in the mat.
wider and thicker waterstops are somewhat easier to construct just because they are a little beefier. if you want to make your tank as leak resistant as possible, use the waterstops. it is relatively cheap insurance. i have used the greenstreak #732 6" wide pvc with center bulb which can tolerate movement and it has worked well.
i know you say waterstop, but is this tank actually for fuel or water?
for all intents and purposes the tank i am designing is a hollow structure in the ground. being "water tight" is not a requirement but i think it is good practice for the "just in case" scenario.
concrete is not water tight, merely water resistant. add a frp liner for true water impermeability.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
waterstops--cast-in vs synkofle huangyhg 产品功能分析 0 2009-09-16 07:17 PM
vertical construction joints 2 4-way wall corners huangyhg 产品功能分析 0 2009-09-16 06:17 PM
ype of waterstop huangyhg 产品功能分析 0 2009-09-16 04:31 PM


所有的时间均为北京时间。 现在的时间是 06:19 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多