默认 olerance for lean of retaining wall

tolerance for lean of retaining wall
hi, i am involved in an investigation regarding a leaning retaining wall. i am trying to write a report and am wondering if anyone knows offhand a code based tolerance for angle of lean (ie. what is/is not acceptable), especially in a canadian context.
thanks

i think this is not a code issue, rather an engineering investigation (on original design and strength of the retaining wall)in conjuction with geotechnical analysis is required.
thre is no acceptablility criteria for lean of a retaining wall that i know of.
i don't know how much the wall needs to actually move to achive the active pressure, but if it is cantilevered retaining wall, it is supposed to move....... again, i don't know how much.
it is not an issue of forward movement for the development of active vs passive pressure or anything like that.
the wall is actually rotating or falling over due to the pressure of the soil behind it. its very obvious to the naked eye; we had it surveyed and its about 8 degrees off a vertical reference line. in other words, an overturning failure. i suspect it was backfilled with the local clay instead of a granular fill.
i was assuming that there must be some kind of tolerance that i could compare it to in my report as even a "properly" designed and constructed retaining wall would be resonably be expected to lean a little bit either backwards or forwards.
thanks
then find out what the angle is for development of active pressure for a typical soil and use that.
i cannot remember an actual maximum deflection criteria for retaining walls. perhaps there should be. but 8 degrees is certainly unacceptable. is this a cantilever wall or a gravity wall? if cantilevered, the failure could be either rotation or stem failure.
retaining walls backfilled with clay are very complicated things. if the clay shrinks and swells with moisture change, cracks will collect debris, changing the volume. where you are the cracks will also collect water and freeze. thus the movement is often gradual (creep) and can continue to move for years.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
retaining wall retaining water huangyhg 产品功能分析 0 2009-09-15 06:41 PM
retaining wall near a river bank huangyhg 产品功能分析 0 2009-09-15 06:39 PM
retaining wall failure huangyhg 产品功能分析 0 2009-09-15 06:38 PM
in enercalc masonry wall design, what is parapet heigh huangyhg 产品功能分析 0 2009-09-09 07:17 PM
cantilever retaining wall or no huangyhg 产品功能分析 0 2009-09-07 10:39 PM


所有的时间均为北京时间。 现在的时间是 03:43 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多