默认 raising roof on existing wood frame building

raising roof on existing wood frame building
we have a client looking at using an existing 50 ft x 215 ft wood building as an assembly shop. the walls are 2x6 @ 16" and the roof are trusses @2' o/c. the current eave height is approx. 12'. the client would like to raise the eave to 24'.
a quick check of the code says he needs 2x10 walls minimum.
so a couple questions :
can the wall be stepped, i.e. 2x10 to 12' and 2x6 above?
the code considers the wall studs pinned at each end. can tie anchors such as the simpsons products be used to provide a fixed end conditions for design purposes?
can the same type of simpson products be used to provide a moment connection at a stud splice?
i have my own opinions on these but a searching for some other perspectives.
thanks
check out our whitepaper library.
designing wood with fixed ends doesn't seem practical, and the splice from a 2x6 to a 2x10 also seems ugly. new studs, full height is the way to go, or try a small steel frame inboard of the existing wall with a horizontal girt at the 12' elevation (saving the lower 2x6 wall). don't allow owners with tight wallets to compromise your engineering judgement.
think of the wall studs as if they were floor joists, because the determining factor is their ability to resist the wind as bending members as well as acting as compression
thanks folks,
just what i expected to hear. but i had to check these off my list of ideas.
you could try attaching a cold-formed steel stud the full height of the wall, and use a 2 x 6 at the top; for design, you may consider the combination as a composite member, or else let the steel stud do all the work, with the wood acting only as a nailer for the sheathing.
you can't get a complete moment connection at the base, so i usually use (wl^2)/9 to compute moment due to wind lateral loading.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
perpendicular roof wind pressures huangyhg 产品功能分析 0 2009-09-15 12:13 PM
perception huangyhg 产品功能分析 0 2009-09-15 12:06 PM
metal building manufacturers huangyhg 产品功能分析 0 2009-09-10 01:36 PM
masonry wall with wood supports for roof huangyhg 产品功能分析 0 2009-09-10 01:01 PM
4 story wood building with steel beams and columns at the fi huangyhg 产品功能分析 0 2009-09-07 08:45 AM


所有的时间均为北京时间。 现在的时间是 05:26 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多