默认 deflection criteria for slate tile wall

deflection criteria for slate tile wall
i am working on a building with a slate tile facade. does anyone know the appropriate deflection criteria to use for the design of curtainwalls and spandrel beams? any help would be much appreciated.
-zach lindauer

for brittle materials, i have seen deflection limits ranging from l/480 to l/640.
thank you for your reply sperlingpe.
perhaps some additional information would be useful. slate tiles are proposed to be attached to 3/4" plywood with hooks. no grout will be used in this application. this will allow the tiles to slip in relation to one another without causing stresses within the tiles.
i believe this is very similar to a slate shingle roof, which would be designed for l/360 total load deflection. does this seem reasonable?
zfl, that is an interesting application that i've not encountered before. slate isn't used much around here. just curious: are the tiles lapped similar to a roof? what is the plywood attached to: metal or wood studs; cmu? unless there is industry data to the contrary and no concern about too much deflection causing leaking problems between the tiles, l/360 would be reasonable in my opinion.
the tiles are arranged in a half-lap pattern. the plywood is attached to metal studs. i have not been able to find any industry data regarding this condition. all opinions on this are very much appreciated.
-zfl
i've looked for info on the 'net, also. nothing so far for slate used for siding.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete seawalli-wall huangyhg 产品功能分析 0 2009-09-08 12:35 PM
concrete basement wall design huangyhg 产品功能分析 0 2009-09-08 11:39 AM
cantilever retaining wall or no huangyhg 产品功能分析 0 2009-09-07 10:39 PM
buttress wall relative rigidity huangyhg 产品功能分析 0 2009-09-07 05:57 PM
brick cladding deflection limits huangyhg 产品功能分析 0 2009-09-07 04:48 PM


所有的时间均为北京时间。 现在的时间是 09:41 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多