默认 curved plywood silltop plates

curved plywood sill/top plates
working on a 20'x40' oval (in plan) structure. the framer used 1 1/8" rated plywood for the curved sill plate, and double 1 1/8" for the top plates. is this typical practice for curved situations? this is the first curved structure i have worked on.
also, how are curved shear walls dealt with? they cut a 1/8" deep vertical cut all the way up the wall every 4 or 5 inches o.c. so they could bend the plywood to fit the wall. obviously, this is no good. what is the norm? what do you suggest for a fix?
thanks!
check out our whitepaper library.
using plywood to cut out curved plates is fairly normal in my area (fl). i can't vouch for the thickness. i would have asked for 3/4-plywood built-up to 1.5-inch and 3-inch thicknesses.
where the plywood is cut, can you use the thickness of the plywood minus the cut depth for your "effective" thickness of shearwall?
i actually detailed 2-2x6 top plate and 2x6 sole plate, contractor chose to ignore that.
the effective thickness would be slightly less than 1/4".
the shear in the walls is minor, and i'm not worried about it, but i would like to have at least the 3/8" thickness. i think i will have them put a 1/4" or a notched 3/8" panel on the outside of the ex. panel. that should take care of it.
the thing you have to watch with the plywood is the bending strength is less than you would have from the sawn lumber you called for. the bearing may also be smaller, i'm not sure. if you don't need that strength then there isn't much difference. most of the time you probably won't. the other is to make sure you have the pressure-treated lumber against the concrete if your code requires it.
your contractor did everything i would have expected. the only way to make curved sill and top plates is to use plywood. how would you curve a 2 x 6?
for the sheathing, i have usually seen 1/4" plywood used, since it is flexible enough to curve.
daveatkins
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
curved concrete beam in elevation huangyhg 产品功能分析 0 2009-09-08 04:10 PM
curved beam huangyhg 产品功能分析 0 2009-09-08 04:08 PM
corrosion of galvanized plates huangyhg 产品功能分析 0 2009-09-08 02:08 PM
apa plywood or apa rated sheathing huangyhg 产品功能分析 0 2009-09-07 12:28 PM
【转帖】asme美国机械工程师标准目录2 huangyhg American standards 5 2009-04-26 02:38 PM


所有的时间均为北京时间。 现在的时间是 09:34 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多