默认 cathodic protection for pier

cathodic protection for pier
i've got a client with a 1/4 mile pier into a brackish (salt and fresh water mix) river.
over time, the painted steel pipe piles have started to corrode. the plant currently uses an impressed current and sacraficial anodes to protect (or reduce) the pile corrosion but this does not appear to be enough.
my initial reaction is a ndt program, and clean and paint; with concrete jacketing on the piles with excessive reduction in thickness.
any other thoughts?
any experience out there with other types of repairs?
as always, thanks for the help.
jjf
if an impressed current system cannot handle the problem, i doubt if other measures will be successful. many years ago i had the opportunity to do some field work with an authority on impressed current systems. as the system works and the sacrificial anodes do their job (i.e. vanish), the applied voltage has to be adjusted (increased) to compensate. we made field measurements of the voltage at various locations on a buried natural gas pipeline network. then based on his experience he adjusted the cathode voltage to maintain protection. of course, over time, the anodes will become so deteriorated that they must be replaced.
suggest you call in a specialist on impressed current systems to check out the present conditions.
on pipelines, i have always used sacrificial anodes until the pipeline is complete. these are then removed and the impressed current switched on. otherwise the two systems fight each other. of course all elements of the structure would have to be electrically connected.
i would agree that a specialised cp company is a definite.
on a recent pipeline, the local dc motor commuter trains were pushing out 1500v onto a leaking negative return rail and the potential on the pipeline was changing by a volt every second. we were collecting hydrogen gas off the line at one stage! could this be a factor?
other thoughts
cement rich concrete may protect the steel without the need for paint, although you may have to remove any salts first.
we have had special paint applied to bare steel underwater by divers.
guys, thanks for the feedback.
stephena - you bring up an interesting point. my pier is handling crude oil in and finished gasoline out. i know they got grounding cabling in differnet areas, but i wonder if they've tested the potential differences during operation.
jjf
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
cable structures and fire protection huangyhg 产品功能分析 0 2009-09-07 06:04 PM
aluminum fire protection huangyhg 产品功能分析 0 2009-09-07 11:19 AM
aircraft lightning protection huangyhg 精密机械 0 2009-09-05 10:18 PM


所有的时间均为北京时间。 现在的时间是 03:54 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多