超级版主
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
|
verifing sr wall segmental retaining wall program calculatio
verifing sr wall segmental retaining wall program calculatio
i was wondering if anyone knows the hand calculations necessary to verify the results of the sr wall computer program for segmental retainig walls. i have tried to compare the computer results with the results in the second edition of the segmental retaining walls design manual and can not get the internal sliding and the internal resisting moment calculations to match between the two. i am looking for the hand calculations necessary to verify the computer data on these two areas.
check out our whitepaper library.
that is certainly something to be concerned about.
look at the software's documentation - see if the method of analysis is clearly indicated. then contact the software company and ask for an explanation (unless the documentation makes the reasons for the differences obvious.) provide them with your design problem, your hand calcs and the program's output.
let us know what you find -
i went through a similar exercise with an srw manufacturer's software, and i was able to match my results with the program's output.
did you see the worked examples in the ncma design manual? if not, you may find some answers there.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
|