旧 2009-09-16, 01:06 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 emporary shielding design

temporary shielding design
i am currnetly in the process of designing debri shielding for a bridge. the exterior parapets and some of the deck is being removed. the exterior portion will be supported by overhang brackets and the interior bay will have wooden 2" x 12" planks resting on the bottom flanges. my basic question is this: where can i find loading information for falling debri or any kind of demo work? i have looked in the aashto construction handbook and guide spec book for temporary work and i can't find anything. i have done overhang falsework design before but i have never done shielding design. it seems to me that falling debri will have more of a load impact than simple dead load but i am not sure how to calculate it. if anyone has any information for me i would appreciate it. thanks.
i would check with osha. they may have some useful information. good luck.
we specify 100 psf live load (impact included) for shielding design in our contract specifications; we also specify that any debris has to be removed within 24 hours.
f=ma
i've seen specs that require, in addition to 100 - 150 psf live load, that the design also be sufficient for a 1000# concentrated load falling 6'.
sheilding design requires a bit of educated guess work as to the loads.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)