查看单个帖子
旧 2009-09-07, 11:01 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 carrying out second order analysis with software

carrying out second order analysis with software
i have used an old dos based software strsolv for structural analysis.
the program takes input for 3d frame, member inertias, loads, and various combinations of dead, live and lateral loads. the program reports moments, shears, axial forces etc for all members, and can even give forces at various segments. the program is also able to calculate, x, y, z displacements and rotations at frame joints.
since i do not know internal working of program, so i am not sure whether software performs first or second order analysis.
assuming that the results are first order one will have to use moment magnification factors on reported results, otherwise for second order can perform direct design on reported values.
is there some rough check or criteria to tell whether reported results are first or second order....
ad what sort of inputs are given to a software for second order analysis.
check out our whitepaper library.
try modelling a 10ft tall flag pole with a 1 kip load horizontal and 100 kip vertical load at the very top. if the moment at the base is 10ft*kips, then it is not accounting for second order effects.(it should be greater than 10). but re
what haynewp said: i agree
what plato said: i agree
jae i thought you were mostly a wine drinker?
he was a wise man who invented beer.
--plato
uh...well, generally a glass of wine every other day or so....beer always has its time and place, though.
not that the clock always reads "beer-thirty"....
your clock must be broke.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖